The most basic function of cooling towers thermal characteristics can be explained in relation to how bodies use sweat to cool down. When the human body gets too hot and it needs to lower down the body temperature, it begins to sweat. Such a process lets down the body temperature and it’s the same way that makes cooling towers thermal characteristics work.
But, there is more water to unheat and vaporize in cooling towers than the little amount of sweat bodies cause. That is why cooling towers add a few factors to the equation. The towers have fans to replace moisture saturated air, while the gears drive to manage the fans, water circulation devices, and a heat source to operate warmth overflow.
To understand the attributes keep on reading the article to gain a comprehensive knowledge of the thermal characteristics of cooling towers services:
Wet Buld Temperature
The wet buld temperature concept is used to recognize the relative humidity, which frequently changes throughout the day.
You can find out the relative humidity by comparing the temperature of a dry thermometer with a wet buld thermometer’s temperature. The system of the wet buld has water placed on it buld then air is passed from it, due to which the water evaporates and thus the temperature is recorded. That is how the process of wet buld temperature functions.
Most commonly, the temperature of both the thermometers might be different at times, but if the air is completely drenched with water, the readings might be alike. When the air has outreach 100% relative humidity, it will no longer accept water, plus the water bulb cannot evaporate and the degrees will remain the same as that of dry buld.
Hence, the lower the wet buld reading, the lesser the humidity, and the more moisture the air can accept, the more heat the cooling tower can reject easily.
Don’t Miss to Read: Cooling Tower and Its Benefits- Explained
Variety of wet bulb readings recorded in order to determine the maximum reading through which you can get to know about the size of the cooling towers. When sizing the cooling tower, you need to double-check on the side caution and measure because if it’s incorrect, then it might be an issue. As such, sometimes the tower will be a huge one, but the leaving water temperature will simply be lower.
Speed Of Cooling Tower Transfering The Heat
Cooling tower services does not include controlling the rate of heat transfer. It only transfers the heat it has been transmitted. However, keep in mind that the heat transfer and evaporation rates do not differ, regardless of the cooling tower’s size.
While the wet-bulb temperature, along with the cooling size and flow rate, also decides inflow and outflow water temperature readings. But, the difference between inlet and outlet is not determined by the cooling towers.
A cooling tower could unheat the water from 90 to 80 degrees or 100 to 90 degrees; the 10 degrees small temperature rise and fall will not affect the size of the cooling tower. Although you cannot change the heat transfer temperature, you can boost performance by increasing the cubic feet per minute or enlarging the surface area of the cooling towers.
The bottom line,
The above is the sum-up of how the cooling tower thermal characteristics work. However, if you have any other queries, you can reach out to Tower Tech; we will help you out with any questions you have. Whether it’s for a natural draft cooling tower or any other services, we will ensure to give you the best efficiency.
We are one of the best cooling tower manufacturers in India. So, if you are looking to conserve your cooling towers, we will provide cleaning and repairing.